VoltaLab06

Compliance voltage: ±30 V

Maximum current output: ±1 A

Polarisation voltage: ±15 V

Slew rate: 10 mV/s

Rise time (100% signal) < 1µs

Bandwidth (-3dB): 800 kHz

Current autoranging

Potential autoranging

 

Voltammetry (DC)

 

Applied DC potential

   Ranges: ±4, ±8, ±15 V

   Best resolution: 125 µV

   Accuracy: ±0.2% of range

Measured potential

   Ranges: ±2, ±4, ±8, ±15 V

   Resolution16 bits (0.003% of range)

   Best resolution: 60 µV

   Accuracy: ±0.2 % of range

   Analogue output: Yes

Measured current

   Ranges: 7 from ±1A to ±1µA

   Best resolution: 30 pA

   Resolution16 bits (0.003% of range)

   Accuracy: ±0.2 % of range

   Analogue output: Yes

Filters

   Automatic mode

   Manual mode: 7 filters

   Anti-oscillation filter

 

Scanning performances

 

Measurement period: 20 ms

Max. scan rate: 500 mV/s

( = 10 mV/20 ms)

Min. scan rate: 125 µV/125s

 

Ohmic Drop Compensation (iR)

 

Static manual & Static  auto


Size &  Weight

485 x 300 x 88 mm & 13 kg

 

VoltaMaster 4 software with VoltaLab 06

 

Useful specifications

 

Tutorial methods

Tutorial Help

Interactive Real time plot

Current autoranging

Potential autoranging

Menu-guided

Colour printing

Curve files in ASCII

Results folder

Multitasking

E-mail link

Windows 95/98/NT/2000/Me compatible

Ohmic Drop Compensation Static

 

Electrochemical methods

 

Open Circuit Potential

Pot. Cyclic Voltammetry

Pot. CV 4 limits

Pot. Tutorial CV

Pot. Interactive CV

Chrono Amperometry

Chrono Coulometry

Chrono Potentiometry

Gal. Coulometry

Pitting corrosion

General corrosion (Rp)

Coupled corrosion (Evans)

Pot. Square WV

Pot. Linear V

Tast polaro

Visual IFV

Visual VFI

Tools

Auto. Linear Extraction

Auto. Traject

Message

Relocate potentials

Jump to method

Save curve as

Last point

Print report

Yes or No?

 

Calculation routines

 

Peak analysis

Integration

Tafel analysis

Linear regression

Circular regression

Stern Analysis

Evans analysis

Coulometric dissolution

Resistance subtraction

 

Curve operation

 

X Y1 Y2 representation

Zoom

Overlay/Remove

Linear extraction

Differential extraction

Potential reset/offset

Current reset/offset

Charge reset/offset

Time reset/offset

Curve addition/subtraction

Append

Export (to Excel 97)

Smoothing

Cursor

Title

Legend

 

Data subject to change without notice

 

VoltaLab 06

   Educational Electrochemical Laboratory consists of one

   PST006 Educational Potentiostat plus one VoltaMaster 4 Electrochemical Software

   version 7.0 or higher and a set of cables.

Minimum PC configuration

   Pentium -RS232 - Mouse - 32 Mbytes RAM - Microsoft Windows 95

Ordering information

   VoltaLab 06 (230 V)          R21V033

   VoltaLab 06 (115 V)          R21V034

Design és programozás: www.webuzem.hu
RADIOMETER COPENHAGEN